  "html_url": "https://postor.com.mx/licitacion/la-50-gyr-050gyr075-t-57-2023",
  "canonical": "https://postor.com.mx/licitacion/la-50-gyr-050gyr075-t-57-2023",
  "id": "c256ee1cdb7f4846a1d597c5cee4205b",
  "procedure_number": "LA-50-GYR-050GYR075-T-57-2023",
  "file_number": "E-2023-00038799",
  "title": "LA-50-GYR-050GYR075-T-57-2023 CONSUMIBLES Y ACCESORIOS PARA ELECTROMIOGRAFIA",
  "description": {
    "short": "No existen bienes alternativos o sustitutos, Único Oferente, Derechos exclusivos (patentes, licencias, derechos de autor u otros derechos exclusivos), o por obras de arte.",
    "detailed": "ADQUISICIÓN DE CONSUMIBLES Y ACCESORIOS PARA ELECTROMIOGRAFIA"
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "ADJUDICADO PARCIAL",
    "moved_at": null
  },
  "buyer": {
    "agency": "IMSS",
    "acronym": "IMSS",
    "branch": "50 - INSTITUTO MEXICANO DEL SEGURO SOCIAL",
    "buying_unit": "COORDINACION DE ABASTECIMIENTO Y EQUIPAMIENTO DELEGACION QUERETARO",
    "requesting_unit": null,
    "requesting_group": "COORDINACION DE ABASTECIMIENTO Y EQUIPAMIENTO DELEGACION QUERETARO",
    "entity": "TESORERÍA DE LA FEDERACIÓN",
    "slug": "imss",
    "unit_slug": "coordinacion-de-abastecimiento-y-equipamiento-delegacion-queretaro-050gyr075"
  },
  "classification": {
    "procedure_type": "LICITACIÓN PÚBLICA",
    "contracting_type": "ADQUISICIONES",
    "publication_type": null,
    "character": "INTERNACIONAL BAJO LA COBERTURA DE TRATADOS",
    "fiscal_year": 2023,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": "1",
    "exception_basis": "Art. 41 fr. I",
    "internal_control_number": "LA-50-GYR-050GYR075-T-57-2023 CONSUMIBLES Y ACCESORIOS PARA ELECTROMIOGRAFIA",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2023-05-26T01:57:29.000Z",
    "clarification_meeting_at": "2023-05-30T17:00:00.000Z",
    "clarification_questions_deadline_at": "2023-05-29T17:00:00.000Z",
    "clarification_responses_deadline_at": null,
    "bid_opening_at": "2023-06-07T17:00:00.000Z",
    "award_at": "2023-06-16T22:00:00.000Z",
    "estimated_contract_at": "2023-06-16T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "locations": {
    "state_id": "22",
    "state": "QUERÉTARO",
    "bid_opening": "COORDINACIÓN DE ABASTECIMIENTO Y EQUIPAMIENTO, AV. MEZQUITAL NO. 6, COL. SAN PABLO, C.P. 76130, QUERÉTARO, QRO. A TRAVÉS DE COMPRANET",
    "award": "COORDINACIÓN DE ABASTECIMIENTO Y EQUIPAMIENTO, AV. MEZQUITAL NO. 6, COL. SAN PABLO, C.P. 76130, QUERÉTARO, QRO.A TRAVÉS DE COMPRANET",
    "clarification_meeting": "COORDINACIÓN DE ABASTECIMIENTO Y EQUIPAMIENTO, AV. MEZQUITAL NO. 6, COL. SAN PABLO, C.P. 76130, QUERÉTARO, QRO.A TRAVES DE COMPRANET",
    "site_visit": null,
    "work_site": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "MXN",
    "updated_at": null
  },
  "financial_terms": {
    "currency": "MXN",
    "advance_percentage": "0",
    "supplier_percentage": "10",
    "payment_method": "DE FORMA ELECTRÓNICA EN UN SOLO PAGO",
    "credit_condition": null,
    "payment_conditions": null,
    "financing_organization": null
  },
  "evaluation": {
    "criterion": "BINARIO",
    "technical_points": null,
    "economic_points": null
  },
  "guarantees": {
    "performance_required": true,
    "goods_or_services_required": true,
    "amount_percentage": null,
    "delivery_days": "10",
    "term_months": "12",
    "other_insurance_required": false,
    "other_insurance_description": null,
    "performance_reduction": null
  },
  "participation": {
    "method": "ELECTRÓNICA",
    "joint": true,
    "msme_only": false,
    "social_witness": false,
    "multi_year": false,
    "open_contract": false,
    "consolidated_purchase": false,
    "external_credit": false,
    "simultaneous_supply": false,
    "subcontracting": null,
    "emergency": false,
    "proposal_language": "idioma data",
    "no_joint_participation_justification": null
  },
  "execution": {
    "site_visit_required": false,
    "duration_days": null,
    "procurement_term": "Recortado",
    "subcontracted_work": null,
    "deadline_justification": "NO SE CUENTA CON EXISTENCIAS EN EL ALMACEN DELEGACIONAL"
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "53101-1510",
          "specific_item_code": "53101",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "description": "ELECTRODO REUSABLE DE BARRA, 1.0 M CABLE. PRESENTACION: PIEZA. NUMERO DECATALOGO: 019-401400. PARA SU USO EN EL EQUIPO: CLAVE 531 333 0317ELECTROMIOGRAFO DE CUATRO CANALES. MARCA: NICOLET. MODELO: VIKINGQUEST.",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null,
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "2",
          "cucop_code": "53101-1510",
          "specific_item_code": "53101",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "description": "ELECTRODO REUSABLE DE TIERRA 1.25 M CABLE. PRESENTACION: PIEZA. NUMERO DECATALOGO: 019-411700. PARA SU USO EN EL EQUIPO: CLAVE 531 333 0317ELECTROMIOGRAFO DE CUATRO CANALES. MARCA: NICOLET. MODELO: VIKINGQUEST.",
          "requested_quantity": "2",
          "minimum_quantity": "2",
          "maximum_quantity": null,
          "unit": "KILOGRAMO POR HORA",
          "minimum_amount": null,
          "maximum_amount": null,
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "3",
          "cucop_code": "53101-1510",
          "specific_item_code": "53101",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "description": "ELECTRODO DE AGUJA MONOPOLAR DESECHABLE 75MM X 25GA X 0.46M (BCO.).PRESENTACION: PIEZA. NUMERO DE CATALOGO: ET-101194. PARA SU USO EN EL EQUIPO:CLAVE: 531.333.0317.01.01 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO MEDICORODABLE. MARCA: XLTEK. MODELO: XCALIBUR.",
          "requested_quantity": "158",
          "minimum_quantity": "158",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null,
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "4",
          "cucop_code": "53101-1510",
          "specific_item_code": "53101",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "description": "ELECTRODO DESECHABLE DE AGUJA MONOPOLAR. LONGITUD: 25 MM. COMPATIBLE CON LASMARCAS: GRASS, CADWELL, NIHON KOHDEN. PRESENTACION: CAJA CON 48 PIEZAS. NUMERODE CATALOGO: 902-DMF25TP. PARA SU USO EN EQUIPO MEDICO: CLAVE 531.333.0317ELECTROMIOGRAFO DE CUATRO CANALES. MARCA: NICOLET VIASYS/HEALTHCARE/CAREFUSION. MODELO: VIKING QUEST.",
          "requested_quantity": "30",
          "minimum_quantity": "30",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null,
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "5",
          "cucop_code": "53101-1510",
          "specific_item_code": "53101",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "description": "ELECTRODO DESECHABLE DE AGUJA MONOPOLAR. LONGITUD: 50 MM. COMPATIBLE CON LASMARCAS: GRASS, CADWELL, NIHON KOHDEN. PRESENTACION: CAJA CON 48 PIEZAS. NUMERODE CATALOGO: 902-DMF50TP. PARA SU USO EN EQUIPO MEDICO: CLAVE 531.333.0317ELECTROMIOGRAFO DE CUATRO CANALES. MARCA: NICOLET VIASYS/HEALTHCARE/CAREFUSION. MODELO: VIKING QUEST.",
          "requested_quantity": "71",
          "minimum_quantity": "71",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null,
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "6",
          "cucop_code": "53101-1510",
          "specific_item_code": "53101",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "description": "ELECTRODO DESECHABLE DE AGUJA MONOPOLAR. LONGITUD: 37 MM. COMPATIBLE CON LASMARCAS: GRASS, CADWELL, NIHON KOHDEN. PRESENTACION: CAJA CON 48 PIEZAS. NUMERODE CATALOGO: 902-DMF37TP. PARA SU USO EN EQUIPO MEDICO: CLAVE 531.333.0317ELECTROMIOGRAFO DE CUATRO CANALES. MARCA: NICOLET VIASYS/HEALTHCARE/CAREFUSION. MODELO: VIKING QUEST.",
          "requested_quantity": "29",
          "minimum_quantity": "29",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null,
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "7",
          "cucop_code": "53101-1510",
          "specific_item_code": "53101",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "description": "ELECTRODO DESECHABLE DE AGUJA MONOPOLAR. LONGITUD: 75 MM. COMPATIBLE CON LASMARCAS: GRASS, CADWELL, NIHON KOHDEN. PRESENTACION: CAJA CON 24 PIEZAS. NUMERODE CATALOGO: 902-DMF75TP. PARA SU USO EN EQUIPO MEDICO: CLAVE 531.333.0317ELECTROMIOGRAFO DE CUATRO CANALES. MARCA: NICOLET VIASYS/HEALTHCARE/CAREFUSION. MODELO: VIKING QUEST.",
          "requested_quantity": "19",
          "minimum_quantity": "19",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null,
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "8",
          "cucop_code": "53101-1510",
          "specific_item_code": "53101",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "description": "ELECTRODO DE CONEXION A TIERRA, TIPO DISCO PRESENTACION: PIEZA. NUMERO DECATALOGO: H658 (NM-550B). PARA SU USO EN EL EQUIPO: ELECTROMIOGRAFO DE CUATROCANALES. CLAVE: 531.333.0317. MARCA: NIHON KOHDEN. MODELO: MEB-9400K.",
          "requested_quantity": "3",
          "minimum_quantity": "3",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null,
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "9",
          "cucop_code": "53101-1510",
          "specific_item_code": "53101",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "description": "ELECTRODO DE SUPERFICIE, LONGITUD 2.3M BANDA AJUSTABLE PRESENTACION: PIEZA.NUMERO DE CATALOGO: H638 (NM-315S). PARA SU USO EN EL EQUIPO: ELECTROMIOGRAFODE CUATRO CANALES. CLAVE: 531.333.0317. MARCA: NIHON KOHDEN. MODELO: MEB-9400K.",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null,
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "10",
          "cucop_code": "53101-1510",
          "specific_item_code": "53101",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "description": "ELECTRODO PARA ESTIMULACION SUPERFICIAL, INOXIDABLE PRESENTACION: PIEZA. NUMERODE CATALOGO: H639 (NM-422B). PARA SU USO EN EL EQUIPO: ELECTROMIOGRAFO DECUATRO CANALES. CLAVE: 531.333.0317. MARCA: NIHON KOHDEN. MODELO: MEB-9400K.",
          "requested_quantity": "10",
          "minimum_quantity": "10",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null,
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "11",
          "cucop_code": "53101-1510",
          "specific_item_code": "53101",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "description": "PASTA CONDUCTORA TEN20. PRESENTACION: TARRO 8 OZ. NUMERO DE CATALOGO:016-703700. PARA SU USO EN EL EQUIPO: CLAVE 531 333 0317 ELECTROMIOGRAFO DECUATRO CANALES. MARCA: NICOLET. MODELO: VIKINGQUEST.",
          "requested_quantity": "5",
          "minimum_quantity": "5",
          "maximum_quantity": null,
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null,
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        }
      ]
    }
  ],
  "budget_items": [
    {
      "code": "53101",
      "description": "EQUIPO MEDICO Y DE LABORATORIO"
    }
  ],
  "awards": [
    {
      "id": "C-2023-00090626",
      "internal_reference": "D233008",
      "title": "LA-50-GYR-050GYR075-T-57-2023 CONSUMIBLES Y ACCESORIOS PARA ELECTROMIOGRAFIA",
      "status": "PUBLICADO",
      "contractor": {
        "name": "CORPORATIVO MS SISTEMAS MEDICOS SA DE CV",
        "normalized_name": "CORPORATIVO MS SISTEMAS MEDICOS",
        "rfc_type": null,
        "slug": "corporativo-ms-sistemas-medicos"
      },
      "contract_period": {
        "published_at": "2023-10-02T23:52:04.000Z",
        "starts_at": "2023-06-16T06:00:00.000Z",
        "ends_at": "2023-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "573510",
        "tax": "91761.6",
        "total": "665271.6",
        "maximum_subtotal": "0",
        "maximum_total": "0",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1510",
          "description": "ELECTRODO DE AGUJA MONOPOLAR DESECHABLE 75MM X 25GA X 0.46M (BCO.).PRESENTACION: PIEZA. NUMERO DE CATALOGO: ET-101194. PARA SU USO EN EL EQUIPO:CLAVE: 531.333.0317.01.01 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO MEDICORODABLE. MARCA: XLTEK. MODELO: XCALIBUR.",
          "unit": "PIEZA",
          "requested_quantity": "158",
          "awarded_quantity": null,
          "unit_price": "105",
          "subtotal": "16590",
          "tax": "2654.4",
          "other_taxes": null,
          "total": "19244.4",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "0",
          "cucop_code": "53101-1510",
          "description": "ELECTRODO DESECHABLE DE AGUJA MONOPOLAR. LONGITUD: 25 MM. COMPATIBLE CON LASMARCAS: GRASS, CADWELL, NIHON KOHDEN. PRESENTACION: CAJA CON 48 PIEZAS. NUMERODE CATALOGO: 902-DMF25TP. PARA SU USO EN EQUIPO MEDICO: CLAVE 531.333.0317ELECTROMIOGRAFO DE CUATRO CANALES. MARCA: NICOLET VIASYS/HEALTHCARE/CAREFUSION. MODELO: VIKING QUEST.",
          "unit": "PIEZA",
          "requested_quantity": "30",
          "awarded_quantity": null,
          "unit_price": "5040",
          "subtotal": "151200",
          "tax": "24192",
          "other_taxes": null,
          "total": "175392",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "0",
          "cucop_code": "53101-1510",
          "description": "ELECTRODO DESECHABLE DE AGUJA MONOPOLAR. LONGITUD: 50 MM. COMPATIBLE CON LASMARCAS: GRASS, CADWELL, NIHON KOHDEN. PRESENTACION: CAJA CON 48 PIEZAS. NUMERODE CATALOGO: 902-DMF50TP. PARA SU USO EN EQUIPO MEDICO: CLAVE 531.333.0317ELECTROMIOGRAFO DE CUATRO CANALES. MARCA: NICOLET VIASYS/HEALTHCARE/CAREFUSION. MODELO: VIKING QUEST.",
          "unit": "PIEZA",
          "requested_quantity": "71",
          "awarded_quantity": null,
          "unit_price": "5040",
          "subtotal": "357840",
          "tax": "57254.4",
          "other_taxes": null,
          "total": "415094.4",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "0",
          "cucop_code": "53101-1510",
          "description": "ELECTRODO DESECHABLE DE AGUJA MONOPOLAR. LONGITUD: 75 MM. COMPATIBLE CON LASMARCAS: GRASS, CADWELL, NIHON KOHDEN. PRESENTACION: CAJA CON 24 PIEZAS. NUMERODE CATALOGO: 902-DMF75TP. PARA SU USO EN EQUIPO MEDICO: CLAVE 531.333.0317ELECTROMIOGRAFO DE CUATRO CANALES. MARCA: NICOLET VIASYS/HEALTHCARE/CAREFUSION. MODELO: VIKING QUEST.",
          "unit": "PIEZA",
          "requested_quantity": "19",
          "awarded_quantity": null,
          "unit_price": "2520",
          "subtotal": "47880",
          "tax": "7660.8",
          "other_taxes": null,
          "total": "55540.8",
          "cucop_description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VERTEX (SVR) DE TALLO CEREBRAL O TALLO ENCEFALICO (PATC O ABR). POTENCIALES EVOCADOS VISUALES: DESTELLO EN GOGGLES DE PATRON INVERSO. ESTIMULADORES: ELECTRICO DE CORRIENTE O VOLTAJE CONSTANTE DE UN CANAL SELECCIONABLE POR EL USUARIO: AMPLITUD DURACION FRECUENCIA (REPETICION DEL ESTIMULO) MODO: SENCILLO DOBLE TREN Y RECURRENTE. ESTIMULACION AUDITIVA CON CONTROLES DE TIPO DE SEÑAL: CLICK Y BURST. FRECUENCIA (REPETICION DEL ESTIMULO) DE INTENSIDAD Y MODO DE CALIBRACION. ESTIMULACION VISUAL CON CONTROLES DE: FRECUENCIA (REPETICION DEL ESTIMULO) PROGRAMA (DERECHO IZQUIERDO Y AMBOS). MONITOR PARA ESTIMULACION VISUAL. ELECTROMIOGRAFO BASADO EN COMPUTADORA PERSONAL. PROCESADOR INTEL PENTIUM II O SIMILAR A 266 MHZ O MAYOR MEMORIA RAM CON 64 MB O MAS DISCO DURO DE 2.1 GB O MAYOR CD ROM 24X O MAYOR TARJETA DE VIDEO DE 64 BITS TECLADO ALFANUMERICO Y RATON. MONITOR A COLOR CON PANTALLA UVGA (DE 1024 X 768 PIXELES). ADQUISICION Y DESPLIEGUE EN TIEMPO REAL. REPORTE DE RESULTADOS COMPATIBLE CON PROCESADOR DE TEXTOS. CAPACIDAD PARA CRECIMIENTO A PROGRAMAS ADICIONALES. INTERRUPTOR DE PIE (PEDAL). AMPLIFICADOR DE CUATRO CANALES CON CABLE Y BRAZO.",
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        }
      ]
    }
  ],
  "documents": [
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "CONVOCATORIA",
      "filename": "CONVOCATORIA electromiografia.docx",
      "availability": "available",
      "size_bytes": "1512728",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-13T01:59:21.080Z",
      "updated_at": "2025-12-13T01:59:21.082Z"
    },
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "AVISO DE DIFERIMIENTO DE FALLO",
      "filename": "diferimiento fallo T57.pdf",
      "availability": "available",
      "size_bytes": "825889",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-13T01:59:39.922Z",
      "updated_at": "2025-12-13T01:59:39.923Z"
    },
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "AVISO DE DIFERIMIENTO DE FALLO",
      "filename": "diferimiento fallo (2) T57.pdf",
      "availability": "available",
      "size_bytes": "891717",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-13T01:59:43.086Z",
      "updated_at": "2025-12-13T01:59:43.088Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "ANEXO TECNICO.pdf",
      "availability": "available",
      "size_bytes": "132871",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-13T01:59:22.413Z",
      "updated_at": "2025-12-13T01:59:22.415Z"
    },
    {
      "id": null,
      "annex_number": 3,
      "document_type": null,
      "description": "MODELO DE CONTRATO",
      "filename": "MODELO DE CONTRATO.docx",
      "availability": "available",
      "size_bytes": "1047016",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-13T01:59:25.404Z",
      "updated_at": "2025-12-13T01:59:25.406Z"
    },
    {
      "id": null,
      "annex_number": 6,
      "document_type": null,
      "description": "ACTA JUNTA DE ACLARACIONES",
      "filename": "junta aclaraciones t57.pdf",
      "availability": "available",
      "size_bytes": "2546460",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-13T01:59:29.514Z",
      "updated_at": "2025-12-13T01:59:29.516Z"
    },
    {
      "id": null,
      "annex_number": 7,
      "document_type": null,
      "description": "ACTA DE APERTURA DE PROPOSICIONES",
      "filename": "PAP T57-23.pdf",
      "availability": "available",
      "size_bytes": "6655341",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-13T01:59:38.033Z",
      "updated_at": "2025-12-13T01:59:38.034Z"
    },
    {
      "id": null,
      "annex_number": 10,
      "document_type": null,
      "description": "ACTA DE FALLO",
      "filename": "ACTA DE FALLO T57-2023.pdf",
      "availability": "available",
      "size_bytes": "5922040",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-13T01:59:49.751Z",
      "updated_at": "2025-12-13T01:59:49.752Z"
    }
  ],
  "provenance": {
    "source_system": "Compras MX",
    "source_fetched_at": "2026-07-28T01:04:05.134Z",
    "last_seen_at": "2026-07-28T02:13:26.583Z",
    "first_seen_at": "2025-11-05T04:41:13.670Z",
    "detail_complete": true,
    "documents_complete": true,
    "content_changed_at": "2025-11-05T04:41:13.670Z"
  },
  "context": {
    "prices": [
      {
        "cucop_code": "53101-1510",
        "description": "531.333.0317 ELECTROMIOGRAFO DE CUATRO CANALES. EQUIPO ELECTROMEDICO RODABLE OPERADO POR MICROPROCESADORES NO INVASIVO PARA LA REALIZACION DE ESTUDIOS DE POTENCIALES EVOCADOS AUDITIVOS VISUALES Y SOMATOSENSORIALES ELECTROMIOGRAFIA VELOCIDAD DE CONDUCCION MOTORA Y SENSORIAL. SISTEMA DE ELECTRODIAGNOSTICO CON PROGRAMAS DE APLICACION PARA ELECTROMIOGRAFIA (EMG) Y POTENCIALES EVOCADOS EN SISTEMA OPERATIVO Y MODO GRAFICO PARA REALIZAR LOS SIGUIENTES ESTUDIOS. ELECTROMIOGRAFIA: POTENCIAL DE UNIDAD MOTORA (MUAP) REFLEJO DE PARPADEO ESTIMULACION REPETITIVA ELECTROMIOGRAFIA DE FIBRA UNICA ONDA F REFLEJO H COLISION. POTENCIALES EVOCADOS SOMATOSENSORIALES: POTENCIAL EVOCADO SOMATOSENSORIAL (SEP) POTENCIAL EVOCADO DE LATENCIA CORTA (SSEP). ESTUDIOS DE CONDUCCION NERVIOSA: VELOCIDAD DE CONDUCCION MOTORA VELOCIDAD DE CONDUCCION SENSORIAL. POTENCIALES EVOCADOS AUDITIVOS (ABR): ELECTROCOCLEOGRAFIA (ECOG) POTENCIALES EVOCADOS DE LATENCIA MEDIA POTENCIALES EVOCADOS DE LATENCIA TARDIA (LLR) O LENTA DE VE",
        "priced_items": 38,
        "units": [
          {
            "n": 37,
            "max": 1123348.44,
            "min": 105,
            "p10": 42576,
            "p50": 800000,
            "p90": 934700,
            "unidad": "PIEZA"
          }
        ],
        "price_by_year": {
          "2023": {
            "n": 20,
            "p50": 800000
          },
          "2024": {
            "n": 7,
            "p50": 677539
          },
          "2025": {
            "n": 6,
            "p50": 922190
          },
          "2026": {
            "n": 5,
            "p50": 113750
          }
        },
        "refreshed_at": "2026-09-18T22:39:28.174Z"
      }
    ],
    "suppliers": [
      {
        "slug": "corporativo-ms-sistemas-medicos",
        "name": "CORPORATIVO MS SISTEMAS MEDICOS SA DE CV",
        "total_contracts": 361,
        "total_awarded_amount": "517557080.11",
        "median_amount": "268675.72",
        "distinct_buyers": 12,
        "first_contract_at": "2023-01-27T00:00:00.000Z",
        "last_contract_at": "2026-09-18T00:00:00.000Z",
        "with_this_buyer": {
          "contracts": 331,
          "amount": "490039224.9"
        },
        "refreshed_at": "2026-09-18T20:32:00.697Z"
      }
    ],
    "buyer": {
      "slug": "imss",
      "name": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "total_procedures": 51299,
      "distinct_suppliers": 8089,
      "procedures_by_type": {
        "LICITACIÓN PÚBLICA": 11359,
        "ADJUDICACIÓN DIRECTA": 35850,
        "INVITACIÓN A CUANDO MENOS TRES PERSONAS": 4079,
        "CONTRATO ESPECÍFICO DERIVADO DE ACUERDO MARCO": 11
      },
      "refreshed_at": "2026-09-27T10:00:02.081Z"
    }
  },
  "alternates": [],
  "similar": [
    {
      "numero_procedimiento": "la-47-ayo-047ayo954-t-370-2024",
      "nombre_procedimiento": "ADQ SUST DE EQUIPO MÉDICO PARA LA ATENCIÓN DE PACIENTES COVID HJM 1 PARTIDA",
      "dependencia": "IMSS-BIENESTAR",
      "siglas": "IMSS-BIENESTAR",
      "score": 0.12642104187136982,
      "anio_ejercicio": 2024,
      "estatus": "DESIERTO",
      "fecha_fallo": "2024-10-24T14:00:00.000Z",
      "fecha_publicacion": "2024-09-05T18:15:54.000Z",
      "ganador": null,
      "ganador_slug": null,
      "ganador_rfc_type": null,
      "ganadores": "0",
      "monto_mxn": null
    },
    {
      "numero_procedimiento": "la-47-ayo-047ayo954-t-240-2025",
      "nombre_procedimiento": "ADQUISICIÓN DE BIENES PARA EL PROGRAMA DE INVERSIÓN DENOMINADO PROGRAMA DE SUSTI",
      "dependencia": "IMSS-BIENESTAR",
      "siglas": "IMSS-BIENESTAR",
      "score": 0.13235885693781557,
      "anio_ejercicio": 2025,
      "estatus": "ADJUDICADO",
      "fecha_fallo": "2025-07-17T14:00:00.000Z",
      "fecha_publicacion": "2025-05-28T21:03:24.000Z",
      "ganador": "MEDIKAL-MUNERIS SA DE CV",
      "ganador_slug": "medikal-muneris",
      "ganador_rfc_type": null,
      "ganadores": "1",
      "monto_mxn": "2048049.60"
    },
    {
      "numero_procedimiento": "la-47-ayo-047ayo954-i-40-2025",
      "nombre_procedimiento": "ADQUISICIÓN BIENES PARA PROGRAMA DE INVERSIÓN DENOMINADO PROGRAMA COVID HJM",
      "dependencia": "IMSS-BIENESTAR",
      "siglas": "IMSS-BIENESTAR",
      "score": 0.1382912223003373,
      "anio_ejercicio": 2025,
      "estatus": "DESIERTO",
      "fecha_fallo": "2025-02-28T14:00:00.000Z",
      "fecha_publicacion": "2025-01-28T18:48:09.000Z",
      "ganador": null,
      "ganador_slug": null,
      "ganador_rfc_type": null,
      "ganadores": "0",
      "monto_mxn": null
    },
    {
      "numero_procedimiento": "la-50-gyr-050gyr010-n-32-2026",
      "nombre_procedimiento": "LA-50-GYR-050GYR010-N-32-2026 ARRENDAMIENTO DE ELECTROMIÓGRAFO DE CUATRO CANALES",
      "dependencia": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "siglas": "IMSS",
      "score": 0.14049074472459355,
      "anio_ejercicio": 2026,
      "estatus": "DESIERTO",
      "fecha_fallo": "2026-04-10T11:00:00.000Z",
      "fecha_publicacion": "2026-03-12T16:54:24.000Z",
      "ganador": null,
      "ganador_slug": null,
      "ganador_rfc_type": null,
      "ganadores": "0",
      "monto_mxn": null
    },
    {
      "numero_procedimiento": "la-50-gyr-050gyr010-t-121-2025",
      "nombre_procedimiento": "LA-50-GYR-050GYR010-T-121-2025 ARRENDAMIENTO ELECTROMIÓGRAFO DE CUATRO CANALES.",
      "dependencia": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "siglas": "IMSS",
      "score": 0.1459865396038782,
      "anio_ejercicio": 2025,
      "estatus": "ADJUDICADO",
      "fecha_fallo": "2025-10-16T11:00:00.000Z",
      "fecha_publicacion": "2025-10-02T16:33:49.000Z",
      "ganador": "GESTUM CONSULTORES SA DE CV",
      "ganador_slug": "gestum-consultores",
      "ganador_rfc_type": null,
      "ganadores": "2",
      "monto_mxn": "827892.00"
    },
    {
      "numero_procedimiento": "la-78-036-919048990-i-10-2024",
      "nombre_procedimiento": "SUMINISTRO DE EQUIPOS E INSUMOS PARA PERSONAS CON DISCAPACIDAD DEL ESTADO DE N.L",
      "dependencia": "DIFNL",
      "siglas": "DIFNL",
      "score": 0.15837087134967098,
      "anio_ejercicio": 2024,
      "estatus": "ADJUDICADO",
      "fecha_fallo": "2024-11-07T11:00:00.000Z",
      "fecha_publicacion": "2024-10-15T12:43:41.000Z",
      "ganador": "DANIEL ALEJANDRO MENDOZA CANTU",
      "ganador_slug": "daniel-alejandro-mendoza-cantu",
      "ganador_rfc_type": null,
      "ganadores": "1",
      "monto_mxn": "1670382.48"
    }
  ]
}