{
  "html_url": "https://postor.com.mx/licitacion/la-50-gyr-050gyr031-t-224-2025",
  "canonical": "https://postor.com.mx/licitacion/la-50-gyr-050gyr031-t-224-2025",
  "id": "ed8d248b749a44ecb1864e2f5fcb2ffa",
  "procedure_number": "LA-50-GYR-050GYR031-T-224-2025",
  "file_number": "E-2025-00084404",
  "title": "ADQUISICIÓN DE EQUIPO MEDICO PARA EL HZG.15 DE HERMOSILLO, SONORA",
  "description": {
    "short": null,
    "detailed": "ADQUISICIÓN DE EQUIPO MEDICO PARA EL HZG.15 DE HERMOSILLO, SONORA"
  },
  "lifecycle": {
    "section": "concluido",
    "source_status": "ADJUDICADO PARCIAL",
    "moved_at": null
  },
  "buyer": {
    "agency": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
    "acronym": "IMSS",
    "branch": "50 - INSTITUTO MEXICANO DEL SEGURO SOCIAL",
    "buying_unit": "COORDINACIÓN DE ABASTECIMIENTO Y EQUIPAMIENTO",
    "requesting_unit": null,
    "requesting_group": "COORDINACIÓN DE ABASTECIMIENTO Y EQUIPAMIENTO",
    "entity": "IMSS",
    "slug": "imss",
    "unit_slug": "coordinacion-de-abastecimiento-y-equipamiento-050gyr031"
  },
  "classification": {
    "procedure_type": "LICITACIÓN PÚBLICA",
    "contracting_type": "ADQUISICIONES",
    "publication_type": null,
    "character": "INTERNACIONAL BAJO LA COBERTURA DE TRATADOS",
    "fiscal_year": 2025,
    "law": "LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO",
    "legal_basis_id": null,
    "exception_basis": null,
    "internal_control_number": "LA0031-00224",
    "supply_source_number": null
  },
  "schedule": {
    "published_at": "2025-09-03T00:46:21.000Z",
    "clarification_meeting_at": "2025-09-09T18:00:00.000Z",
    "clarification_questions_deadline_at": "2025-09-08T18:00:00.000Z",
    "clarification_responses_deadline_at": null,
    "bid_opening_at": "2025-09-24T18:00:00.000Z",
    "award_at": "2025-10-07T20:00:00.000Z",
    "estimated_contract_at": "2025-10-07T06:00:00.000Z",
    "site_visit_at": null,
    "estimated_work_start_at": null
  },
  "locations": {
    "state_id": "26",
    "state": "SONORA",
    "bid_opening": "COORDINACIÓN DE ABASTECIMIENTO Y EQUIPAMIENTO, UBICADA EN CALLE PROLONGACIÓN HIDALGO Y HUISAGUAY S/N, COLONIA: BELLAVISTA, C.P. 85130, CIUDAD OBREGÓN, SONORA.",
    "award": "COORDINACIÓN DE ABASTECIMIENTO Y EQUIPAMIENTO, UBICADA EN CALLE PROLONGACIÓN HIDALGO Y HUISAGUAY S/N, COLONIA: BELLAVISTA, C.P. 85130, CIUDAD OBREGÓN, SONORA.",
    "clarification_meeting": "COORDINACIÓN DE ABASTECIMIENTO Y EQUIPAMIENTO, UBICADA EN CALLE PROLONGACIÓN HIDALGO Y HUISAGUAY S/N, COLONIA: BELLAVISTA, C.P. 85130, CIUDAD OBREGÓN, SONORA.",
    "site_visit": null,
    "work_site": null
  },
  "estimated_value": {
    "minimum": null,
    "maximum": null,
    "currency": "MXN",
    "updated_at": null
  },
  "financial_terms": {
    "currency": "MXN",
    "advance_percentage": "0",
    "supplier_percentage": "10",
    "payment_method": "TRANSFERENCIA BANCARIA",
    "credit_condition": null,
    "payment_conditions": null,
    "financing_organization": null
  },
  "evaluation": {
    "criterion": "PUNTOS Y PORCENTAJES",
    "technical_points": "50",
    "economic_points": "50"
  },
  "guarantees": {
    "performance_required": true,
    "goods_or_services_required": false,
    "amount_percentage": null,
    "delivery_days": "10",
    "term_months": null,
    "other_insurance_required": false,
    "other_insurance_description": null,
    "performance_reduction": null
  },
  "participation": {
    "method": "ELECTRÓNICA",
    "joint": true,
    "msme_only": false,
    "social_witness": false,
    "multi_year": false,
    "open_contract": true,
    "consolidated_purchase": false,
    "external_credit": false,
    "simultaneous_supply": false,
    "subcontracting": null,
    "emergency": false,
    "proposal_language": "idioma data",
    "no_joint_participation_justification": null
  },
  "execution": {
    "site_visit_required": false,
    "duration_days": null,
    "procurement_term": "Recortado",
    "subcontracted_work": null,
    "deadline_justification": "ARTÍCULO 42 DE LA LEY DE ADQUISICIONES ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO; ASÍ COMO EL ARTÍCULO 43 DEL REGLAMENTO DE LA LEY DE ADQUISICIONES, ARRENDAMIENTOS Y SERVICIOS DEL SECTOR PÚBLICO."
  },
  "lots": [
    {
      "number": "1",
      "name": "PARTIDA SOLA",
      "description": "PARTIDA SOLA",
      "requirement_group_id": "1",
      "items": [
        {
          "number": "1",
          "cucop_code": "53101-1447",
          "specific_item_code": "53101",
          "cucop_description": "531.254.0155 TOMOGRAFIA COMPUTARIZADA MULTICORTES DE 64 CORTES UNIDAD PARA. EQUIPO DE RAYOS X PARA REALIZAR ESTUDIOS TOMOGRAFICOS DE 64 CORTES POR GIRO O ROTACION DE DIFERENTES PARTES DEL CUERPO CON FINES DIAGNOSTICOS. CON UN TIEMPO DE EXPLORACION O RASTREO DE 0.4 SEG O MENOR EN UN GIRO O ROTACION DE 360 °. RESOLUCION TEMPORAL. GANTRY: ANGULACION DE ±30 GRADOS O MAYOR Y APERTURA DE 70 CENTIMETROS O MAYOR. MESA DE PACIENTE: CAPACIDAD DE CARGA DE LA MESA DE 180 KILOGRAMOS O MAYOR. SISTEMA DE POSICIONAMIENTO EN 2 EJES (VERTICAL Y HORIZONTAL). ALINEACION EN AL MENOS TRES EJES PARA DEFINIR EL PLANO DE CORTE. SISTEMA DE RAYOS X: TUBO DE RAYOS X CON CAPACIDAD DE ALMACENAMIENTO DE CALOR EN EL ANODO DE 7.5 MHU O MAYOR. CAPACIDAD DE DISIPACION DE CALOR. CON ESPESOR DE CORTE DE 0.625 MM O MENOR POR 64 CORTES EN HELICOIDAL. GENERADOR DE RAYOS X. CAMPO DE RASTREO O FOV DE 50 CM O MAYOR. PROCESAMIENTO DE IMAGENES: RECONSTRUCCION DE IMAGEN DE 16 IMAGENES POR SEGUNDO O MAYOR. RESOLUCION ESPACIAL. MATRIZ DE RECONSTRUCCION. MATRIZ DE DESPLIEGUE DE 1024X1024 O MAYOR. RECONSTRUCCION DE CONJUNTOS DE CORTES TRIDIMENSIONALES O 3D. RECONSTRUCCION DE VOLUMENES Y SUPERFICIES QUE PERMITA ROTACION ZOOM Y SEGMENTACION DE ORGANOS. CONSOLA DEL OPERADOR O ESTACION DE ADQUISICION: DOS MONITORES CON PANTALLA PLANA O LCD A COLOR DE ALTA RESOLUCION MATRIZ DE DESPLIEGUE DE 1024 X 1024 O MAYOR. CAPACIDAD DE ALMACENAJE DE IMAGENES EN DISCO DURO DE 140 GB O MAYOR. CAPACIDAD DE ALMACENAJE EXTERNO DE IMAGENES EN CD O DVD. CON PROGRAMAS PARA APLICACION DIAGNOSTICA: HERRAMIENTAS BASICAS PARA IMAGENES: ZOOM ROTACION IMAGEN ESPECULAR O EN ESPEJO ESCALA DE GRISES DISTANCIAS VOLUMENES. PROGRAMAS ESPECIFICOS PARA: REDUCCION DE DOSIS DE RADIACION PARA PEDIATRIA. MPR (PROYECCION MULTIPLANAR) EN TIEMPO REAL EN POR LO MENOS TRES PLANOS. DICOM PRINT QUERY/RETRIEVE STORAGE Y WORKLIST.",
          "description": "UNIDAD PARA TOMOGRAFIA AXIAL COMPUTARIZADA DE ALTA RESOLUCION",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": "1",
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null,
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "2",
          "cucop_code": "53101-1537",
          "specific_item_code": "53101",
          "cucop_description": "531.341.2529 UNIDAD RADIOLOGICA Y FLUOROSCOPICA CON TELEMANDO Y ARCO EN ŠCŠ CON MESA BASCULABLE. SISTEMA DE RAYOS \"\"X\"\" MULTIPROPOSITO PARA APLICACIONES RADIOGRAFICAS FLUOROSCOPICAS ANGIOGRAFICAS E INTERVENCIONALES. MESA DE RAYOS \"\"X\"\" TELECOMANDADA CON BRAZO TIPO \"\"C\"\" PARA MONTAJE DEL TUBO E INTENSIFICADOR DE IMAGEN CON COBERTURA DE PACIENTE DE AL MENOS 120 CM. CON SISTEMA DE PROTECCION DE CHOQUES. GENERADOR GENERADOR TRIFASICO DE RAYOS \"\"X\"\" DE ALTA FRECUENCIA CONTROLADO MEDIANTE MICROPROCESADORES Y SISTEMA DE PROTECCION DE ERROR CON PROTECCION CONTRA SOBRECARGA DEL TUBO POTENCIA DE 80 KW COMO MINIMO Y AL MENOS 1000 MA DE CORRIENTE MAXIMA TIEMPO DE EXPOSICION DE 2 MS O MENOR CON AJUSTE DE VOLTAJE ENTRE 40 KW O MENOR HASTA 125 KW O MAYOR CONTROL AUTOMATICO DE EXPOSICION CONTROL AUTOMATICO DE BRILLO. CON CONSOLA DE CONTROL DE MANDO CERCANO Y TELEMANDO. TUBO DE RAYOS \"\"X\"\" 9000 R.P.M. COMO MINIMO CON PUNTO FOCAL FINO NO MAYOR A 0.6 MM Y PUNTO FOCAL GRUESO NO MAYOR A 1.2 MM. CON CAPACIDAD DE ACUMULACION DE CALOR EN EL ANODO DE AL MENOS 300 KHU. MESA PACIENTE TELEMANDO BASCULABLE 85°/ -45° SUSPENDIDA DE UN SOLO PUNTO Y CONO PARA COMPRESION MANEJADO A CONTROL REMOTO ALTURA DE LA MESA VARIABLE DESDE 90 CM O MENOR HASTA 120 CM. O MAYOR DESPLAZAMIENTO LATERAL DEL TABLERO DE LA MESA DE AL MENOS + 12.5 CM. Y 20 CM O DESPLAZAMIENTO LATERAL DEL BRAZO EN C DE AL MENOS + 13 CM Y DE - 15 CM. CARACTERISTICAS DEL BRAZO DESPLAZAMIENTO LONGITUDINAL DEL BRAZO C DE AL MENOS 125 CM. CON VELOCIDAD CONTINUAMENTE VARIABLE ROTACION DEL BRAZO EN C DE 90 ° LAO COMO MINIMO HASTA AL MENOS 40 ° RAO ANGULACION CRANEO - CAUDAL DEL BRAZO EN C DE POR LO MENOS ± 30 ° EN POSICION A.P Y P.A. CON VELOCIDAD VARIABLE. INTENSIFICADOR DE IMAGEN DE 35 CM O MAYOR CON AL MENOS 3 CAMPOS 35/25/17 CM O MAYOR Y SISTEMA DE DETECCION DE COLISION INCORPORADO DOS MONITORES DE T.V. CON LAS SIGUIENTES CARACTERISTICAS: ALTA RESOLUCION DE 1049 AJUSTE AUTOMATICO DE BRILLO PANTALLA DE 50 CM O MAYOR CON SUSPENSION AL TECHO. CON SISTEMA DIGITAL DE ADQUISICION DE IMAGENES EN 1024 X 1024 PIXELES Y 10 BITS QUE CUENTE CON: AL MENOS 64 MBYTES DE MEMORIA RAM O EN DISCO ADQUISICION DE 7.5 IMAGENES POR SEGUNDO O MAYOR DISCO OPTICO MAGNETICO CON CAPACIDAD MINIMA DE 600 MB O MAYOR SUSTRACCION DIGITAL EN TIEMPO REAL DESPLIEGUE DE 16 IMAGENES. CONTROL REMOTO PARA SELECCION DE IMAGENES CONSOLA CON TECLADO ALFANUMERICO Y MONITOR DE 53 CM O MAYOR Y 1000 LINEAS O MAYOR CON PROGRAMAS PARA PROCESAMIENTO DE LA IMAGEN QUE AL MENOS PERMITAN EL REALCE DE BORDES ADAPTACION DEL BRILLO RE-ENMASCARAMIENTO CORRECCION EN TIEMPO REAL O FILTRO PARA CORRECCIONES DINAMICAS DE LOS ARTEFACTOS POR MOVIMIENTO ZOOM Y ANOTACION DE TEXTO.",
          "description": "UNIDAD RADIOLOGICA Y FLUOROSCOPICA DIGITAL CON TELEMANDO. EQ",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": "1",
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null,
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "3",
          "cucop_code": "53101-1447",
          "specific_item_code": "53101",
          "cucop_description": "531.254.0155 TOMOGRAFIA COMPUTARIZADA MULTICORTES DE 64 CORTES UNIDAD PARA. EQUIPO DE RAYOS X PARA REALIZAR ESTUDIOS TOMOGRAFICOS DE 64 CORTES POR GIRO O ROTACION DE DIFERENTES PARTES DEL CUERPO CON FINES DIAGNOSTICOS. CON UN TIEMPO DE EXPLORACION O RASTREO DE 0.4 SEG O MENOR EN UN GIRO O ROTACION DE 360 °. RESOLUCION TEMPORAL. GANTRY: ANGULACION DE ±30 GRADOS O MAYOR Y APERTURA DE 70 CENTIMETROS O MAYOR. MESA DE PACIENTE: CAPACIDAD DE CARGA DE LA MESA DE 180 KILOGRAMOS O MAYOR. SISTEMA DE POSICIONAMIENTO EN 2 EJES (VERTICAL Y HORIZONTAL). ALINEACION EN AL MENOS TRES EJES PARA DEFINIR EL PLANO DE CORTE. SISTEMA DE RAYOS X: TUBO DE RAYOS X CON CAPACIDAD DE ALMACENAMIENTO DE CALOR EN EL ANODO DE 7.5 MHU O MAYOR. CAPACIDAD DE DISIPACION DE CALOR. CON ESPESOR DE CORTE DE 0.625 MM O MENOR POR 64 CORTES EN HELICOIDAL. GENERADOR DE RAYOS X. CAMPO DE RASTREO O FOV DE 50 CM O MAYOR. PROCESAMIENTO DE IMAGENES: RECONSTRUCCION DE IMAGEN DE 16 IMAGENES POR SEGUNDO O MAYOR. RESOLUCION ESPACIAL. MATRIZ DE RECONSTRUCCION. MATRIZ DE DESPLIEGUE DE 1024X1024 O MAYOR. RECONSTRUCCION DE CONJUNTOS DE CORTES TRIDIMENSIONALES O 3D. RECONSTRUCCION DE VOLUMENES Y SUPERFICIES QUE PERMITA ROTACION ZOOM Y SEGMENTACION DE ORGANOS. CONSOLA DEL OPERADOR O ESTACION DE ADQUISICION: DOS MONITORES CON PANTALLA PLANA O LCD A COLOR DE ALTA RESOLUCION MATRIZ DE DESPLIEGUE DE 1024 X 1024 O MAYOR. CAPACIDAD DE ALMACENAJE DE IMAGENES EN DISCO DURO DE 140 GB O MAYOR. CAPACIDAD DE ALMACENAJE EXTERNO DE IMAGENES EN CD O DVD. CON PROGRAMAS PARA APLICACION DIAGNOSTICA: HERRAMIENTAS BASICAS PARA IMAGENES: ZOOM ROTACION IMAGEN ESPECULAR O EN ESPEJO ESCALA DE GRISES DISTANCIAS VOLUMENES. PROGRAMAS ESPECIFICOS PARA: REDUCCION DE DOSIS DE RADIACION PARA PEDIATRIA. MPR (PROYECCION MULTIPLANAR) EN TIEMPO REAL EN POR LO MENOS TRES PLANOS. DICOM PRINT QUERY/RETRIEVE STORAGE Y WORKLIST.",
          "description": "UNIDAD RADIOGRAFICA DE 500 MA CUBIERTA DESPLAZABLE. (DIGITAL",
          "requested_quantity": "1",
          "minimum_quantity": "1",
          "maximum_quantity": "1",
          "unit": "PIEZA",
          "minimum_amount": null,
          "maximum_amount": null,
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        }
      ]
    }
  ],
  "budget_items": [
    {
      "code": "53101",
      "description": "EQUIPO MEDICO Y DE LABORATORIO"
    }
  ],
  "awards": [
    {
      "id": "C-2025-00106727",
      "internal_reference": "050GYR031T22425-001-00",
      "title": "ADQUISICIÓN DE EQUIPO MEDICO PARA EL HZG.15 DE HERMOSILLO, SONORA",
      "status": "PUBLICADO",
      "contractor": {
        "name": "ELECTRONICA Y MEDICINA SA",
        "normalized_name": "ELECTRONICA Y MEDICINA",
        "rfc_type": null,
        "slug": "electronica-y-medicina"
      },
      "contract_period": {
        "published_at": "2025-10-07T21:30:30.000Z",
        "starts_at": "2025-10-07T06:00:00.000Z",
        "ends_at": "2025-12-31T06:00:00.000Z"
      },
      "value": {
        "subtotal": "3227200",
        "tax": "516352",
        "total": "3743552",
        "maximum_subtotal": "8068000",
        "maximum_total": "9358880",
        "currency": "MXN"
      },
      "open_contract_type": null,
      "quantity": null,
      "exercised_quantity": null,
      "participants": [],
      "line_items": [
        {
          "number": "0",
          "cucop_code": "53101-1537",
          "description": "UNIDAD RADIOLOGICA Y FLUOROSCOPICA DIGITAL CON TELEMANDO. EQ",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "5699000",
          "subtotal": "2279600",
          "tax": "364736",
          "other_taxes": null,
          "total": "2644336",
          "cucop_description": "531.341.2529 UNIDAD RADIOLOGICA Y FLUOROSCOPICA CON TELEMANDO Y ARCO EN ŠCŠ CON MESA BASCULABLE. SISTEMA DE RAYOS \"\"X\"\" MULTIPROPOSITO PARA APLICACIONES RADIOGRAFICAS FLUOROSCOPICAS ANGIOGRAFICAS E INTERVENCIONALES. MESA DE RAYOS \"\"X\"\" TELECOMANDADA CON BRAZO TIPO \"\"C\"\" PARA MONTAJE DEL TUBO E INTENSIFICADOR DE IMAGEN CON COBERTURA DE PACIENTE DE AL MENOS 120 CM. CON SISTEMA DE PROTECCION DE CHOQUES. GENERADOR GENERADOR TRIFASICO DE RAYOS \"\"X\"\" DE ALTA FRECUENCIA CONTROLADO MEDIANTE MICROPROCESADORES Y SISTEMA DE PROTECCION DE ERROR CON PROTECCION CONTRA SOBRECARGA DEL TUBO POTENCIA DE 80 KW COMO MINIMO Y AL MENOS 1000 MA DE CORRIENTE MAXIMA TIEMPO DE EXPOSICION DE 2 MS O MENOR CON AJUSTE DE VOLTAJE ENTRE 40 KW O MENOR HASTA 125 KW O MAYOR CONTROL AUTOMATICO DE EXPOSICION CONTROL AUTOMATICO DE BRILLO. CON CONSOLA DE CONTROL DE MANDO CERCANO Y TELEMANDO. TUBO DE RAYOS \"\"X\"\" 9000 R.P.M. COMO MINIMO CON PUNTO FOCAL FINO NO MAYOR A 0.6 MM Y PUNTO FOCAL GRUESO NO MAYOR A 1.2 MM. CON CAPACIDAD DE ACUMULACION DE CALOR EN EL ANODO DE AL MENOS 300 KHU. MESA PACIENTE TELEMANDO BASCULABLE 85°/ -45° SUSPENDIDA DE UN SOLO PUNTO Y CONO PARA COMPRESION MANEJADO A CONTROL REMOTO ALTURA DE LA MESA VARIABLE DESDE 90 CM O MENOR HASTA 120 CM. O MAYOR DESPLAZAMIENTO LATERAL DEL TABLERO DE LA MESA DE AL MENOS + 12.5 CM. Y 20 CM O DESPLAZAMIENTO LATERAL DEL BRAZO EN C DE AL MENOS + 13 CM Y DE - 15 CM. CARACTERISTICAS DEL BRAZO DESPLAZAMIENTO LONGITUDINAL DEL BRAZO C DE AL MENOS 125 CM. CON VELOCIDAD CONTINUAMENTE VARIABLE ROTACION DEL BRAZO EN C DE 90 ° LAO COMO MINIMO HASTA AL MENOS 40 ° RAO ANGULACION CRANEO - CAUDAL DEL BRAZO EN C DE POR LO MENOS ± 30 ° EN POSICION A.P Y P.A. CON VELOCIDAD VARIABLE. INTENSIFICADOR DE IMAGEN DE 35 CM O MAYOR CON AL MENOS 3 CAMPOS 35/25/17 CM O MAYOR Y SISTEMA DE DETECCION DE COLISION INCORPORADO DOS MONITORES DE T.V. CON LAS SIGUIENTES CARACTERISTICAS: ALTA RESOLUCION DE 1049 AJUSTE AUTOMATICO DE BRILLO PANTALLA DE 50 CM O MAYOR CON SUSPENSION AL TECHO. CON SISTEMA DIGITAL DE ADQUISICION DE IMAGENES EN 1024 X 1024 PIXELES Y 10 BITS QUE CUENTE CON: AL MENOS 64 MBYTES DE MEMORIA RAM O EN DISCO ADQUISICION DE 7.5 IMAGENES POR SEGUNDO O MAYOR DISCO OPTICO MAGNETICO CON CAPACIDAD MINIMA DE 600 MB O MAYOR SUSTRACCION DIGITAL EN TIEMPO REAL DESPLIEGUE DE 16 IMAGENES. CONTROL REMOTO PARA SELECCION DE IMAGENES CONSOLA CON TECLADO ALFANUMERICO Y MONITOR DE 53 CM O MAYOR Y 1000 LINEAS O MAYOR CON PROGRAMAS PARA PROCESAMIENTO DE LA IMAGEN QUE AL MENOS PERMITAN EL REALCE DE BORDES ADAPTACION DEL BRILLO RE-ENMASCARAMIENTO CORRECCION EN TIEMPO REAL O FILTRO PARA CORRECCIONES DINAMICAS DE LOS ARTEFACTOS POR MOVIMIENTO ZOOM Y ANOTACION DE TEXTO.",
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        },
        {
          "number": "0",
          "cucop_code": "53101-1447",
          "description": "UNIDAD RADIOGRAFICA DE 500 MA CUBIERTA DESPLAZABLE. (DIGITAL",
          "unit": "PIEZA",
          "requested_quantity": "1",
          "awarded_quantity": null,
          "unit_price": "2369000",
          "subtotal": "947600",
          "tax": "151616",
          "other_taxes": null,
          "total": "1099216",
          "cucop_description": "531.254.0155 TOMOGRAFIA COMPUTARIZADA MULTICORTES DE 64 CORTES UNIDAD PARA. EQUIPO DE RAYOS X PARA REALIZAR ESTUDIOS TOMOGRAFICOS DE 64 CORTES POR GIRO O ROTACION DE DIFERENTES PARTES DEL CUERPO CON FINES DIAGNOSTICOS. CON UN TIEMPO DE EXPLORACION O RASTREO DE 0.4 SEG O MENOR EN UN GIRO O ROTACION DE 360 °. RESOLUCION TEMPORAL. GANTRY: ANGULACION DE ±30 GRADOS O MAYOR Y APERTURA DE 70 CENTIMETROS O MAYOR. MESA DE PACIENTE: CAPACIDAD DE CARGA DE LA MESA DE 180 KILOGRAMOS O MAYOR. SISTEMA DE POSICIONAMIENTO EN 2 EJES (VERTICAL Y HORIZONTAL). ALINEACION EN AL MENOS TRES EJES PARA DEFINIR EL PLANO DE CORTE. SISTEMA DE RAYOS X: TUBO DE RAYOS X CON CAPACIDAD DE ALMACENAMIENTO DE CALOR EN EL ANODO DE 7.5 MHU O MAYOR. CAPACIDAD DE DISIPACION DE CALOR. CON ESPESOR DE CORTE DE 0.625 MM O MENOR POR 64 CORTES EN HELICOIDAL. GENERADOR DE RAYOS X. CAMPO DE RASTREO O FOV DE 50 CM O MAYOR. PROCESAMIENTO DE IMAGENES: RECONSTRUCCION DE IMAGEN DE 16 IMAGENES POR SEGUNDO O MAYOR. RESOLUCION ESPACIAL. MATRIZ DE RECONSTRUCCION. MATRIZ DE DESPLIEGUE DE 1024X1024 O MAYOR. RECONSTRUCCION DE CONJUNTOS DE CORTES TRIDIMENSIONALES O 3D. RECONSTRUCCION DE VOLUMENES Y SUPERFICIES QUE PERMITA ROTACION ZOOM Y SEGMENTACION DE ORGANOS. CONSOLA DEL OPERADOR O ESTACION DE ADQUISICION: DOS MONITORES CON PANTALLA PLANA O LCD A COLOR DE ALTA RESOLUCION MATRIZ DE DESPLIEGUE DE 1024 X 1024 O MAYOR. CAPACIDAD DE ALMACENAJE DE IMAGENES EN DISCO DURO DE 140 GB O MAYOR. CAPACIDAD DE ALMACENAJE EXTERNO DE IMAGENES EN CD O DVD. CON PROGRAMAS PARA APLICACION DIAGNOSTICA: HERRAMIENTAS BASICAS PARA IMAGENES: ZOOM ROTACION IMAGEN ESPECULAR O EN ESPEJO ESCALA DE GRISES DISTANCIAS VOLUMENES. PROGRAMAS ESPECIFICOS PARA: REDUCCION DE DOSIS DE RADIACION PARA PEDIATRIA. MPR (PROYECCION MULTIPLANAR) EN TIEMPO REAL EN POR LO MENOS TRES PLANOS. DICOM PRINT QUERY/RETRIEVE STORAGE Y WORKLIST.",
          "partida_code": "53101",
          "partida_description": "EQUIPO MEDICO Y DE LABORATORIO"
        }
      ]
    }
  ],
  "documents": [
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "CONVOCATORIA",
      "filename": "CONVOCATORIA.docx",
      "availability": "available",
      "size_bytes": "14714895",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:58:41.944Z",
      "updated_at": "2025-12-02T10:58:41.945Z"
    },
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "AVISO DE DIFERIMIENTO DE FECHA Y HORA DE APERTURA DE PROPOSICIONES",
      "filename": "AVISO LA-T-224.pdf",
      "availability": "available",
      "size_bytes": "112395",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:01:41.312Z",
      "updated_at": "2025-12-02T11:01:41.313Z"
    },
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "AVISO DE DIFERIMIENTO DE FALLO",
      "filename": "1ER DIF FALLO.pdf",
      "availability": "available",
      "size_bytes": "1376923",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:02:11.125Z",
      "updated_at": "2025-12-02T11:02:11.126Z"
    },
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "AVISO DE DIFERIMIENTO DE FALLO",
      "filename": "DIF FALLO.pdf",
      "availability": "available",
      "size_bytes": "139653",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:02:13.734Z",
      "updated_at": "2025-12-02T11:02:13.735Z"
    },
    {
      "id": null,
      "annex_number": 1,
      "document_type": null,
      "description": "AVISO DE DIFERIMIENTO DE FALLO",
      "filename": "DIF FALLO T-224.pdf",
      "availability": "available",
      "size_bytes": "146011",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:02:15.085Z",
      "updated_at": "2025-12-02T11:02:15.086Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "ANEXO TECNICO.pdf",
      "availability": "available",
      "size_bytes": "1627829",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:19.837Z",
      "updated_at": "2025-12-02T10:59:19.839Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 3 2.xlsx",
      "availability": "available",
      "size_bytes": "130943",
      "mime_type": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:21.906Z",
      "updated_at": "2025-12-02T10:59:21.907Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 3 3.xlsx",
      "availability": "available",
      "size_bytes": "157686",
      "mime_type": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:23.779Z",
      "updated_at": "2025-12-02T10:59:23.780Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 3 4.xlsx",
      "availability": "available",
      "size_bytes": "230312",
      "mime_type": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:25.341Z",
      "updated_at": "2025-12-02T10:59:25.342Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 3 5.xlsx",
      "availability": "available",
      "size_bytes": "131249",
      "mime_type": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:27.073Z",
      "updated_at": "2025-12-02T10:59:27.074Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 3 AT.docx",
      "availability": "available",
      "size_bytes": "406497",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:28.662Z",
      "updated_at": "2025-12-02T10:59:28.664Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 1.docx",
      "availability": "available",
      "size_bytes": "403433",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:30.102Z",
      "updated_at": "2025-12-02T10:59:30.103Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 10.docx",
      "availability": "available",
      "size_bytes": "390360",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:32.969Z",
      "updated_at": "2025-12-02T10:59:32.970Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 11.pdf",
      "availability": "available",
      "size_bytes": "186788",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:35.757Z",
      "updated_at": "2025-12-02T10:59:35.758Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 12.xlsx",
      "availability": "available",
      "size_bytes": "130751",
      "mime_type": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:37.145Z",
      "updated_at": "2025-12-02T10:59:37.146Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 13 2.xlsx",
      "availability": "available",
      "size_bytes": "131087",
      "mime_type": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:38.374Z",
      "updated_at": "2025-12-02T10:59:38.448Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 13.xlsx",
      "availability": "available",
      "size_bytes": "164078",
      "mime_type": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:39.704Z",
      "updated_at": "2025-12-02T10:59:39.706Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 14.docx",
      "availability": "available",
      "size_bytes": "390780",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:41.424Z",
      "updated_at": "2025-12-02T10:59:41.425Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 15.docx",
      "availability": "available",
      "size_bytes": "390494",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:42.973Z",
      "updated_at": "2025-12-02T10:59:42.974Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 2.docx",
      "availability": "available",
      "size_bytes": "261707",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:46.547Z",
      "updated_at": "2025-12-02T10:59:46.548Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 3.docx",
      "availability": "available",
      "size_bytes": "469386",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:49.345Z",
      "updated_at": "2025-12-02T10:59:49.346Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 4.docx",
      "availability": "available",
      "size_bytes": "392409",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:50.760Z",
      "updated_at": "2025-12-02T10:59:50.761Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 5.xlsx",
      "availability": "available",
      "size_bytes": "36835",
      "mime_type": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:52.574Z",
      "updated_at": "2025-12-02T10:59:52.575Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 6.xlsx",
      "availability": "available",
      "size_bytes": "36934",
      "mime_type": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:53.722Z",
      "updated_at": "2025-12-02T10:59:53.723Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 7.docx",
      "availability": "available",
      "size_bytes": "626818",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:55.517Z",
      "updated_at": "2025-12-02T10:59:55.519Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 8.docx",
      "availability": "available",
      "size_bytes": "394259",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:59.949Z",
      "updated_at": "2025-12-02T10:59:59.951Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 9.docx",
      "availability": "available",
      "size_bytes": "392238",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:00:02.900Z",
      "updated_at": "2025-12-02T11:00:02.901Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Anexo 4 T yC.docx",
      "availability": "available",
      "size_bytes": "473382",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:00:07.018Z",
      "updated_at": "2025-12-02T11:00:07.019Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "CEDULA 11813.pdf",
      "availability": "available",
      "size_bytes": "848108",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:00:13.390Z",
      "updated_at": "2025-12-02T11:00:13.391Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "CEDULA 11814.pdf",
      "availability": "available",
      "size_bytes": "639253",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:00:17.985Z",
      "updated_at": "2025-12-02T11:00:17.986Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "CEDULA 21174.pdf",
      "availability": "available",
      "size_bytes": "1268996",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:00:22.357Z",
      "updated_at": "2025-12-02T11:00:22.358Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "Economica.xlsx",
      "availability": "available",
      "size_bytes": "16782",
      "mime_type": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:00:23.486Z",
      "updated_at": "2025-12-02T11:00:23.487Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "REQUERIMIENTO.docx",
      "availability": "available",
      "size_bytes": "14367",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:00:24.627Z",
      "updated_at": "2025-12-02T11:00:24.628Z"
    },
    {
      "id": null,
      "annex_number": 2,
      "document_type": null,
      "description": "ANEXO TÉCNICO",
      "filename": "TYC.pdf",
      "availability": "available",
      "size_bytes": "16587952",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:00:58.374Z",
      "updated_at": "2025-12-02T11:00:58.375Z"
    },
    {
      "id": null,
      "annex_number": 3,
      "document_type": null,
      "description": "MODELO DE CONTRATO",
      "filename": "MODELO.docx",
      "availability": "available",
      "size_bytes": "76641",
      "mime_type": "application/vnd.openxmlformats-officedocument.wordprocessingml.document",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:58:43.194Z",
      "updated_at": "2025-12-02T10:58:43.195Z"
    },
    {
      "id": null,
      "annex_number": 4,
      "document_type": null,
      "description": "ANEXOS CONVOCATORIA",
      "filename": "3DA7D.zip",
      "availability": "available",
      "size_bytes": "2331164",
      "mime_type": "application/zip",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:58:50.481Z",
      "updated_at": "2025-12-02T10:58:50.482Z"
    },
    {
      "id": null,
      "annex_number": 5,
      "document_type": null,
      "description": "AVISO DE SUSPENSIÓN DE JUNTA DE ACLARACIONES",
      "filename": "SUSP JA T-224.pdf",
      "availability": "available",
      "size_bytes": "1676786",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:58:55.723Z",
      "updated_at": "2025-12-02T10:58:55.724Z"
    },
    {
      "id": null,
      "annex_number": 6,
      "document_type": null,
      "description": "AVISO DE SUSPENSIÓN DE JUNTA DE ACLARACIONES",
      "filename": "2DO RECESO.pdf",
      "availability": "available",
      "size_bytes": "1690636",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:07.217Z",
      "updated_at": "2025-12-02T10:59:07.218Z"
    },
    {
      "id": null,
      "annex_number": 7,
      "document_type": null,
      "description": "AVISO DE SUSPENSIÓN DE JUNTA DE ACLARACIONES",
      "filename": "3ER RECESO.pdf",
      "availability": "available",
      "size_bytes": "186609",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T10:59:08.923Z",
      "updated_at": "2025-12-02T10:59:08.924Z"
    },
    {
      "id": null,
      "annex_number": 10,
      "document_type": null,
      "description": "ACTA JUNTA DE ACLARACIONES",
      "filename": "JA T-224.pdf",
      "availability": "available",
      "size_bytes": "7552474",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:01:11.070Z",
      "updated_at": "2025-12-02T11:01:11.071Z"
    },
    {
      "id": null,
      "annex_number": 11,
      "document_type": null,
      "description": "ACTA CIERRE JUNTA DE ACLARACIONES",
      "filename": "CIERRE JA T224.pdf",
      "availability": "available",
      "size_bytes": "2977259",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:01:35.837Z",
      "updated_at": "2025-12-02T11:01:35.838Z"
    },
    {
      "id": null,
      "annex_number": 13,
      "document_type": null,
      "description": "ACTA DE APERTURA Y PRESENTACION DE PROPOSICIONES",
      "filename": "CIERRE JA T224.pdf",
      "availability": "available",
      "size_bytes": "610097",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:01:46.831Z",
      "updated_at": "2025-12-02T11:01:46.832Z"
    },
    {
      "id": null,
      "annex_number": 14,
      "document_type": null,
      "description": "ACTA DE APERTURA DE PROPOSICIONES",
      "filename": "AP LA-T224.pdf",
      "availability": "available",
      "size_bytes": "6425722",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:02:04.853Z",
      "updated_at": "2025-12-02T11:02:04.854Z"
    },
    {
      "id": null,
      "annex_number": 18,
      "document_type": null,
      "description": "ACTA DE FALLO",
      "filename": "FALLO LA-T-224.pdf",
      "availability": "available",
      "size_bytes": "33876319",
      "mime_type": "application/pdf",
      "sha256": null,
      "uploaded_at": "2025-12-02T11:03:28.249Z",
      "updated_at": "2025-12-02T11:03:28.250Z"
    }
  ],
  "provenance": {
    "source_system": "Compras MX",
    "source_fetched_at": "2026-08-04T04:46:57.299Z",
    "last_seen_at": "2026-08-04T04:46:57.275Z",
    "first_seen_at": "2025-11-04T22:23:43.101Z",
    "detail_complete": true,
    "documents_complete": true,
    "content_changed_at": "2025-11-04T22:23:43.101Z"
  },
  "context": {
    "prices": [
      {
        "cucop_code": "53101-1537",
        "description": "531.341.2529 UNIDAD RADIOLOGICA Y FLUOROSCOPICA CON TELEMANDO Y ARCO EN ŠCŠ CON MESA BASCULABLE. SISTEMA DE RAYOS \"\"X\"\" MULTIPROPOSITO PARA APLICACIONES RADIOGRAFICAS FLUOROSCOPICAS ANGIOGRAFICAS E INTERVENCIONALES. MESA DE RAYOS \"\"X\"\" TELECOMANDADA CON BRAZO TIPO \"\"C\"\" PARA MONTAJE DEL TUBO E INTENSIFICADOR DE IMAGEN CON COBERTURA DE PACIENTE DE AL MENOS 120 CM. CON SISTEMA DE PROTECCION DE CHOQUES. GENERADOR GENERADOR TRIFASICO DE RAYOS \"\"X\"\" DE ALTA FRECUENCIA CONTROLADO MEDIANTE MICROPROCESADORES Y SISTEMA DE PROTECCION DE ERROR CON PROTECCION CONTRA SOBRECARGA DEL TUBO POTENCIA DE 80 KW COMO MINIMO Y AL MENOS 1000 MA DE CORRIENTE MAXIMA TIEMPO DE EXPOSICION DE 2 MS O MENOR CON AJUSTE DE VOLTAJE ENTRE 40 KW O MENOR HASTA 125 KW O MAYOR CONTROL AUTOMATICO DE EXPOSICION CONTROL AUTOMATICO DE BRILLO. CON CONSOLA DE CONTROL DE MANDO CERCANO Y TELEMANDO. TUBO DE RAYOS \"\"X\"\" 9000 R.P.M. COMO MINIMO CON PUNTO FOCAL FINO NO MAYOR A 0.6 MM Y PUNTO FOCAL GRUESO NO MAYOR A 1.2 MM. CON CAPACID",
        "priced_items": 4,
        "units": [
          {
            "n": 4,
            "max": 11202100,
            "min": 5699000,
            "p10": 6775427.573,
            "p50": 9470654.54,
            "p90": 10737735.151,
            "unidad": "PIEZA"
          }
        ],
        "price_by_year": {
          "2024": {
            "n": 3,
            "p50": 9654217.17
          },
          "2025": {
            "n": 1,
            "p50": 5699000
          }
        },
        "refreshed_at": "2026-09-18T22:39:28.174Z"
      },
      {
        "cucop_code": "53101-1447",
        "description": "531.254.0155 TOMOGRAFIA COMPUTARIZADA MULTICORTES DE 64 CORTES UNIDAD PARA. EQUIPO DE RAYOS X PARA REALIZAR ESTUDIOS TOMOGRAFICOS DE 64 CORTES POR GIRO O ROTACION DE DIFERENTES PARTES DEL CUERPO CON FINES DIAGNOSTICOS. CON UN TIEMPO DE EXPLORACION O RASTREO DE 0.4 SEG O MENOR EN UN GIRO O ROTACION DE 360 °. RESOLUCION TEMPORAL. GANTRY: ANGULACION DE ±30 GRADOS O MAYOR Y APERTURA DE 70 CENTIMETROS O MAYOR. MESA DE PACIENTE: CAPACIDAD DE CARGA DE LA MESA DE 180 KILOGRAMOS O MAYOR. SISTEMA DE POSICIONAMIENTO EN 2 EJES (VERTICAL Y HORIZONTAL). ALINEACION EN AL MENOS TRES EJES PARA DEFINIR EL PLANO DE CORTE. SISTEMA DE RAYOS X: TUBO DE RAYOS X CON CAPACIDAD DE ALMACENAMIENTO DE CALOR EN EL ANODO DE 7.5 MHU O MAYOR. CAPACIDAD DE DISIPACION DE CALOR. CON ESPESOR DE CORTE DE 0.625 MM O MENOR POR 64 CORTES EN HELICOIDAL. GENERADOR DE RAYOS X. CAMPO DE RASTREO O FOV DE 50 CM O MAYOR. PROCESAMIENTO DE IMAGENES: RECONSTRUCCION DE IMAGEN DE 16 IMAGENES POR SEGUNDO O MAYOR. RESOLUCION ESPACIAL. MATR",
        "priced_items": 9,
        "units": [
          {
            "n": 9,
            "max": 22380000,
            "min": 2369000,
            "p10": 10047824.8,
            "p50": 18605750,
            "p90": 22300000,
            "unidad": "PIEZA"
          }
        ],
        "price_by_year": {
          "2023": {
            "n": 1,
            "p50": 11967531
          },
          "2024": {
            "n": 4,
            "p50": 18807875
          },
          "2025": {
            "n": 3,
            "p50": 15000000
          },
          "2026": {
            "n": 1,
            "p50": 22380000
          }
        },
        "refreshed_at": "2026-09-18T22:39:27.668Z"
      }
    ],
    "suppliers": [
      {
        "slug": "electronica-y-medicina",
        "name": "ELECTRONICA Y MEDICINA SA",
        "total_contracts": 206,
        "total_awarded_amount": "2551162944.41",
        "median_amount": "1494080.00",
        "distinct_buyers": 21,
        "first_contract_at": "2023-01-01T00:00:00.000Z",
        "last_contract_at": "2026-08-31T00:00:00.000Z",
        "with_this_buyer": {
          "contracts": 106,
          "amount": "1836541124"
        },
        "refreshed_at": "2026-09-16T00:56:30.797Z"
      }
    ],
    "buyer": {
      "slug": "imss",
      "name": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "total_procedures": 51299,
      "distinct_suppliers": 8089,
      "procedures_by_type": {
        "LICITACIÓN PÚBLICA": 11359,
        "ADJUDICACIÓN DIRECTA": 35850,
        "INVITACIÓN A CUANDO MENOS TRES PERSONAS": 4079,
        "CONTRATO ESPECÍFICO DERIVADO DE ACUERDO MARCO": 11
      },
      "refreshed_at": "2026-09-27T22:00:01.726Z"
    }
  },
  "alternates": [],
  "similar": [
    {
      "numero_procedimiento": "la-50-gyr-050gyr040-t-3-2025",
      "nombre_procedimiento": "PROGRAMA DE ADQUISICION DE EQUIPO MEDICO 2025 (PUNTOS Y PORCENTAJES)",
      "dependencia": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "siglas": "IMSS",
      "score": 0.11057982192518045,
      "anio_ejercicio": 2025,
      "estatus": "CANCELADO",
      "fecha_fallo": "2025-08-25T17:55:00.000Z",
      "fecha_publicacion": "2025-06-06T17:32:11.000Z",
      "ganador": null,
      "ganador_slug": null,
      "ganador_rfc_type": null,
      "ganadores": "0",
      "monto_mxn": null
    },
    {
      "numero_procedimiento": "la-50-gyr-050gyr010-t-66-2024",
      "nombre_procedimiento": "LA-50-GYR-050GYR010-T-66-2024 EQUIPO MÉDICO DE ANGIOGRAFO ARCO MONOPLANAR HGZ 1",
      "dependencia": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "siglas": "IMSS",
      "score": 0.12354211526606473,
      "anio_ejercicio": 2024,
      "estatus": "ADJUDICADO",
      "fecha_fallo": "2024-07-05T11:00:00.000Z",
      "fecha_publicacion": "2024-05-06T14:54:59.000Z",
      "ganador": "HEALTHCARE SYSTEMS DE MEXICO SA DE CV",
      "ganador_slug": "healthcare-systems-de-mexico",
      "ganador_rfc_type": null,
      "ganadores": "1",
      "monto_mxn": "31088000.00"
    },
    {
      "numero_procedimiento": "la-50-gyr-050gyr040-t-12-2024",
      "nombre_procedimiento": "PROGRAMA NACIONAL DE EQUIPOS MÉDICOS TERCERA FASE 2024 RADIODIAGNÓSTICO (PUNTOS)",
      "dependencia": "IMSS",
      "siglas": "IMSS",
      "score": 0.125116229057312,
      "anio_ejercicio": 2024,
      "estatus": "ADJUDICADO",
      "fecha_fallo": "2024-09-27T16:30:00.000Z",
      "fecha_publicacion": "2024-08-27T17:49:29.000Z",
      "ganador": "EUREKA SALUD SA DE CV",
      "ganador_slug": "eureka-salud",
      "ganador_rfc_type": null,
      "ganadores": "2",
      "monto_mxn": "636301147.55"
    },
    {
      "numero_procedimiento": "la-50-gyr-050gyr022-t-110-2024",
      "nombre_procedimiento": "ADQUISICIÓN DE EQUIPAMIENTO ASOCIADO A OBRA (01 CLAVE)",
      "dependencia": "IMSS",
      "siglas": "IMSS",
      "score": 0.13154660087267722,
      "anio_ejercicio": 2024,
      "estatus": "ADJUDICADO",
      "fecha_fallo": "2024-04-26T11:00:00.000Z",
      "fecha_publicacion": "2024-04-09T13:12:04.000Z",
      "ganador": "CONDUIT LIFE SA DE CV",
      "ganador_slug": "conduit-life",
      "ganador_rfc_type": null,
      "ganadores": "1",
      "monto_mxn": "26220397.56"
    },
    {
      "numero_procedimiento": "la-47-ayo-047ayo954-t-288-2024",
      "nombre_procedimiento": "EQUIPAMIENTO EN UNIDADES MÉDICAS HOSPITALARIAS EN LA CIUDAD DE MÉXICO 1 PARTIDA",
      "dependencia": "IMSS-BIENESTAR",
      "siglas": "IMSS-BIENESTAR",
      "score": 0.13516328141579836,
      "anio_ejercicio": 2024,
      "estatus": "ADJUDICADO",
      "fecha_fallo": "2024-08-21T12:00:00.000Z",
      "fecha_publicacion": "2024-07-04T21:21:23.000Z",
      "ganador": "MANTENIMIENTO PREVENTIVO Y CORRECTIVO SA DE CV",
      "ganador_slug": "mantenimiento-preventivo-y-correctivo",
      "ganador_rfc_type": null,
      "ganadores": "1",
      "monto_mxn": "42256480.00"
    },
    {
      "numero_procedimiento": "la-50-gyr-050gyr025-t-104-2025",
      "nombre_procedimiento": "ROGRAMA DE ADQUISICIÓN DE EQUIPAMIENTO PARA UNA NUEVA SALA DE HEMODINAMIA",
      "dependencia": "INSTITUTO MEXICANO DEL SEGURO SOCIAL",
      "siglas": "IMSS",
      "score": 0.13877386681877624,
      "anio_ejercicio": 2025,
      "estatus": "ADJUDICADO",
      "fecha_fallo": "2025-10-17T13:00:00.000Z",
      "fecha_publicacion": "2025-09-30T17:24:49.000Z",
      "ganador": "GRUPO INSOMA S A P I DE CV",
      "ganador_slug": "grupo-insoma",
      "ganador_rfc_type": null,
      "ganadores": "1",
      "monto_mxn": "32685569.62"
    }
  ]
}