{
  "ocid": "ocds-x-licitia-la-50-gyr-050gyr022-t-221-2025",
  "id": "LA-50-GYR-050GYR022-T-221-2025",
  "date": "2025-11-04T22:16:46.003Z",
  "language": "es",
  "initiationType": "tender",
  "tag": [
    "tender",
    "award",
    "contract"
  ],
  "parties": [
    {
      "id": "IMSS",
      "name": "IMSS",
      "roles": [
        "buyer"
      ]
    },
    {
      "id": "MEDICAL ADVANCED SUPPLIES SA DE CV",
      "name": "MEDICAL ADVANCED SUPPLIES SA DE CV",
      "roles": [
        "supplier"
      ]
    },
    {
      "id": "SERVICIOS DE INGENIERIA EN MEDICINA SA DE CV",
      "name": "SERVICIOS DE INGENIERIA EN MEDICINA SA DE CV",
      "roles": [
        "supplier"
      ]
    }
  ],
  "buyer": {
    "id": "IMSS",
    "name": "IMSS"
  },
  "tender": {
    "id": "LA-50-GYR-050GYR022-T-221-2025",
    "title": "LA-50-GYR-050GYR022-T-221-2025 ADQUISICIÓN DE EQUIPOS MÉDICOS SINIESTRADOS",
    "description": "LA-50-GYR-050GYR022-T-221-2025 LICITACIÓN PÚBLICA INTERNACIONAL BAJO LA COBERTURA DE TRATADOS DE LIBRE COMERCIO ELECTRÓNICA, PARA LA ADQUISICIÓN DE BIENES CORRESPONDIENTES AL PROGRAMA DE ADQUISICIÓN DE EQUIPOS MÉDICOS SINIESTRADOS 2025, PARA EL RÉGIMEN ORDINARIO, CUBRIENDO NECESIDADES EN EL ÁMBITO DEL ÓRGANO DE OPERACIÓN ADMINISTRATIVA DESCONCENTRADA REGIONAL VERACRUZ SUR DEL INSTITUTO MEXICANO DEL SEGURO SOCIAL.",
    "status": "complete",
    "procurementMethod": "open",
    "procurementMethodDetails": "LICITACIÓN PÚBLICA",
    "awardCriteriaDetails": "BINARIO",
    "mainProcurementCategory": "goods",
    "tenderPeriod": {
      "startDate": "2025-08-15T00:48:00.000Z",
      "endDate": "2025-08-27T16:00:00.000Z"
    },
    "awardPeriod": {
      "endDate": "2025-09-05T17:00:00.000Z"
    },
    "items": [
      {
        "id": "0",
        "description": "VENTILADOR ADULTO-PEDIATRICO",
        "classification": {
          "scheme": "CUCOP",
          "id": "53101-1859",
          "description": "531.941.0972 VENTILADOR ADULTO PEDIATRICO. EQUIPO ELECTROMECANICO CONTROLADO POR MICROPROCESADOR DE SOPORTE DE VIDA PARA APOYO VENTILATORIO EN PACIENTES ADULTOS Y PEDIATRICOS QUE TIENEN COMPROMETIDA LA FUNCION RESPIRATORIA. CON PANTALLA A COLOR QUE MUESTRE GRAFICAS DATOS NUMERICOS ALARMAS PRIORIZADAS EN TIEMPO REAL Y LOS DIFERENTES MODOS VENTILATORIOS SELECCIONADOS PARA UN ADECUADO TRATAMIENTO. PANTALLA INTERCONSTRUIDA: TIPO LCD LCD-TFT O TFT O LED. A COLOR. TAMAÑO MINIMO DE 10Š (25 CM) O MAYOR CONFIGURABLE POR EL USUARIO. CARACTERISTICAS GENERALES: MEZCLADOR DE AIRE-OXIGENO INTERNO. MONITOREO FIO2 INTERNO O INTEGRADO. SENSOR DE FLUJO REUSABLE. CON SISTEMA DE COMPENSACION DE FUGAS. HUMIDIFICADOR SERVOCONTROLADO PARA USO CON CALENTADOR DE TUBO SENCILLO O DUAL; CON SENSOR DE TEMPERATURA SENCILLO O DUAL DE SOPORTE AL VENTILADOR. TODO EL SISTEMA EN IDIOMA ESPAÑOL. TECLADO SENSIBLE AL TACTO O DE MEMBRANA; O PERILLA SELECTORA PARA EL AJUSTE DE LOS VALORES DE TODOS LOS PARAMETROS DE CONTROL. CONTROL DE PARAMETROS DE: VOLUMEN CORRIENTE QUE CUBRA EL RANGO DE 50 A 2000 ML. FLUJO INSPIRATORIO O FLUJO ADAPTATIVO QUE CUBRA EL RANGO DE 10 A 140 L/MIN. PRESION INSPIRATORIA QUE CUBRA EL RANGO DE 5 A 60 CMH2O. FRECUENCIA RESPIRATORIA QUE CUBRA EL RANGO DE 1 A 80 RESPIRACIONES POR MINUTO. TIEMPO INSPIRATORIO QUE CUBRA EL RANGO DE 0.3 A 5 SEGUNDOS. FIO2 QUE CUBRA EL RANGO DE 21 A 100 %. PEEP/CPAP QUE CUBRA EL RANGO DE 1 A 35 CMH2O. PRESION SOPORTE (PSV) PRESION ASISTIDA O ASB QUE CUBRA EL RANGO DE 0 A 50 CMH2O. CON OPCION MESETA INSPIRATORIA DE PLATEU O PAUSA INSPIRATORIA. CON OPCION DE PAUSA ESPIRATORIA DE 0 A 2 SEGUNDOS O MAYOR. CON OPCION A RESPIRACION MANUAL. SALIDA PARA NEBULIZADOR O NEBULIZADOR SINCRONICO ULTRASONICO O ELECTRICO. MECANISMO DE DISPARO O TRIGGER POR FLUJO Y/O POR PRESION. SENSIBILIDAD ESPIRATORIA O TERMINACION DE LA FASE INSPIRATORIA. BIAS FLOW FLUJO BASE CONTINUO O CPAP. AJUSTE DE RAMPA DE PRESION RISE TIME RETARDO INSPIRATORIO RAMPA O INCREMENTO DE LA PENDIENTE DE PRESION 100% DE O2 DE 2 MINUTOS O MAYOR. MODOS VENTILATORIOS: VENTILACION ASISTO CONTROLADA Y SIMV CONTROLADA POR VOLUMEN.VENTILACION ASISTO CONTROLADA Y SIMV CONTROLADA POR PRESION. PRESION SOPORTE (PSV) O PRESION ASISTIDA. CPAP O ESPONTANEO CON LINEA DE BASE ELEVADA. RESPALDO EN CASO DE APNEA DE ACUERDO AL MODO VENTILATORIO POR VOLUMEN O PRESION. VENTILACION NO INVASIVA. PARAMETROS MONITORIZADOS: PRESION INSPIRATORIA PICO O MAXIMA. PRESION MEDIA EN VIAS AEREAS. PRESION DE MESETA O PLATEAU. PEEP. FRECUENCIA RESPIRATORIA. VOLUMEN MINUTO. RELACION I:E. VOLUMEN CORRIENTE EXHALADO. FIO2. INDICADOR DE HORAS DE USO. INDICADOR DE BATERIA DE RESPALDO EN USO. CALCULO DE DISTENSIBILIDAD O COMPLIANCE. CALCULO DE LA RESISTENCIA. DESPLIEGUE DE AL MENOS 2 DE LAS 3 CURVAS DE VENTILACION DE FORMA SIMULTANEA: VOLUMEN- TIEMPO; FLUJO-TIEMPO; PRESION-TIEMPO. DESPLIEGUE DE AL MENOS 2 LAZOS O LOOPS. CAPACIDAD DE ALMACENAR EVENTOS RELACIONADOS CON LOS PARAMETROS VENTILATORIOS SELECCIONADOS Y TENDENCIAS AL MENOS DE 24 HORAS. MEDICION DE AUTOPEEP O PEEPTOTAL. ALARMAS: AUDIBLES Y VISUALES AMBAS PRIORIZADAS EN TRES NIVELES. PRESION INSPIRATORIA ALTA Y BAJA. PEEP BAJO O DESCONEXION DEL PACIENTE. APNEA. VOLUMEN MINUTO Y/O CORRIENTE (ALTO Y BAJO). FRECUENCIA RESPIRATORIA ALTA. FIO2 ALTA Y BAJA. BAJA PRESION DEL SUMINISTRO DE GASES. FALTA DE ALIMENTACION ELECTRICA. BATERIA BAJA. VENTILADOR INOPERANTE O FALLA DEL VENTILADOR. SILENCIO DE ALARMA. ACCESORIOS INCLUIDOS: BRAZO SOPORTE PARA CIRCUITO DE PACIENTE. BASE RODABLE PARA EL EQUIPO CON SISTEMA DE FRENO EN AL MENOS DOS RUEDAS. BATERIA DE RESPALDO INTERNA CON DURACION DE 60 MINUTOS DE RESPALDO COMO MINIMO. MANGUERAS PARA SUMINISTRO DE GAS DE ACUERDO AL CODIGO AMERICANO DE COLORES: O2 - VERDE AIRE - AMARILLO; PUDIENDO SE AIRE Y OXIGENO O SOLO OXIGENO SEGUN MARCA Y MODELO. REGULADORES DE PRESION INTEGRADOS PARA EL SUMINISTRO DE GASES. DOS CIRCUITOS DE PACIENTE ADULTO REUSABLES LIBRES DE LATEX (INCLUYE ADAPTADORES CONECTORES Y TRAMPAS DE AGUA) O"
        },
        "quantity": 1,
        "additionalClassifications": [
          {
            "scheme": "CUCOP-partida",
            "id": "53101",
            "description": "EQUIPO MEDICO Y DE LABORATORIO"
          }
        ],
        "unit": {
          "name": "UNIDAD",
          "value": {
            "amount": 820000,
            "currency": "MXN"
          }
        }
      },
      {
        "id": "0",
        "description": "VENTILADOR DE TRASLADO PEDIATR",
        "classification": {
          "scheme": "CUCOP",
          "id": "53101-1858",
          "description": "531.941.0279 VENTILADOR DE TRASLADO PEDIATRICO-ADULTO. EQUIPO ELECTROMECANICO PORTATIL CONTROLADO POR MICROPROCESADOR CON BATERIA INTERNA DE SOPORTE DE VIDA PARA APOYO VENTILATORIO EN PACIENTES PEDIATRICOS Y ADULTOS QUE TIENEN COMPROMETIDA LA FUNCION RESPIRATORIA Y REQUIEREN TRASLADOS INTRA O EXTRA-HOSPITALARIOS EN TODO TIPO DE AMBULANCIAS O EN SITIOS DE EMERGENCIA. CON PANTALLA MONOCROMATICA O A COLOR QUE MUESTRE GRAFICAS DATOS NUMERICOS Y ALARMAS. PESO NO MAYOR DE 7 KG. PANTALLA INTERCONSTRUIDA: TIPO LCD LCD-TFT TFT O LED. A COLOR O MONOCROMATICA. TAMAÑO DE 5.7\"\" O MAYOR. CONFIGURABLE POR EL USUARIO. CARACTERISTICAS GENERALES: MEZCLADOR DE AIRE-OXIGENO INTERNO O INTEGRADO Y DE LA MISMA MARCA. MONITOREO DE FIO2 INTERNO. SENSOR DE FLUJO REUSABLE. COMPENSACION AUTOMATICA DE LA ALTITUD. DURACION DE LA BATERIA DE RESPALDO (EXTERNA Y/O INTERNA) DE 4 HORAS COMO MINIMO. TIEMPO DE RECARGA DE LA BATERIA DE 5 HORAS COMO MAXIMO. ASA Y SOPORTE PARA CAMILLA. TODO EL SISTEMA EN IDIOMA ESPAÑOL. PERILLA SELECTORA PARA EL AJUSTE DE LOS VALORES DE TODOS LOS PARAMETROS DE CONTROL. CONTROL DE PARAMETROS DE: VOLUMEN CORRIENTE QUE CUBRA EL RANGO DE 50 A 2000 ML. FLUJO INSPIRATORIO DE 100 L/MIN O MAYOR. PRESION INSPIRATORIA QUE CUBRA EL RANGO DE 5 A 55 CMH2O. FRECUENCIA RESPIRATORIA QUE CUBRA EL RANGO DE 2 A 60 RESPIRACIONES POR MINUTO. TIEMPO INSPIRATORIO QUE CUBRA EL RANGO DE 0.3 A 3 SEGUNDOS. FIO2 QUE CUBRA EL RANGO DE 40 A 100 %. PEEP/CPAP QUE CUBRA EL RANGO DE 0 A 20 CMH2O. PRESION SOPORTE (PSV) PRESION ASISTIDA O ASB QUE CUBRA EL RANGO DE 0 A 35 CMH2O. CON OPCION MESETA INSPIRATORIA DE PLATEU O PAUSA INSPIRATORIA. RESPIRACION MANUAL. SENSIBILIDAD ESPIRATORIA O TERMINACION DE LA FASE INSPIRATORIA. AJUSTE DE RAMPA DE PRESION RISE TIME RETARDO INSPIRATORIO RAMPA O INCREMENTO DE LA PENDIENTE DE PRESION. 100% DE O2 DURANTE 2 MINUTOS O MAS. MECANISMO DE DISPARO O TRIGGER POR FLUJO Y/O POR PRESION. MODOS VENTILATORIOS: VENTILACION ASISTO CONTROLADA Y SIMV CONTROLADA POR VOLUMEN. VENTILACION ASISTO CONTROLADA Y SIMV CONTROLADA POR PRESION. VENTILACION MANDATORIA INTERMITENTE (SIMV) CON PRESION SOPORTE. PRESION SOPORTE (PSV) O PRESION ASISTIDA O ASB. CPAP O ESPONTANEO CON LINEA DE BASE ELEVADA. RESPALDO EN CASO DE APNEA DE ACUERDO AL MODO VENTILATORIO POR VOLUMEN O PRESION. VENTILACION NO INVASIVA. PARAMETROS MONITORIZADOS: PRESION INSPIRATORIA PICO O MAXIMA. PRESION MEDIA EN VIAS AEREAS. PRESION DE MESETA O PLATEAU. VOLUMEN CORRIENTE INSPIRADO Y ESPIRADO. VOLUMEN MINUTO. PEEP. FRECUENCIA RESPIRATORIA. RELACION I:E. TIEMPO INSPIRATORIO (S). FIO2. CALCULO DE DISTENSIBILIDAD Y/O RESISTENCIA. INDICADOR DE HORAS DE USO. INDICADOR DEL ESTADO DE LA BATERIA DE RESPALDO EN USO. DESPLIEGUE DE AL MENOS 2 DE LAS 3 CURVAS DE VENTILACION DE FORMA SIMULTANEA: VOLUMEN-TIEMPO; FLUJO-TIEMPO; PRESION-TIEMPO. ALARMAS: AUDIBLES Y VISUALES. PRESION INSPIRATORIA ALTA Y BAJA. PEEP BAJO O DESCONEXION DEL PACIENTE. APNEA. VOLUMEN MINUTO Y/O CORRIENTE (ALTO Y BAJO). FRECUENCIA RESPIRATORIA ALTA. FIO2 ALTA Y BAJA. BAJA PRESION DEL SUMINISTRO DE GASES. FALLA DE ALIMENTACION ELECTRICA. BATERIA BAJA. VENTILADOR INOPERANTE FALLA DEL VENTILADOR FALLA TECNICA O FALLA DE CICLO. SILENCIO DE ALARMA. PROGRAMACION AUTOMATICA DE ALARMAS. ACCESORIOS INCLUIDOS: MANGUERA PARA SUMINISTRO DE GAS DE ACUERDO AL CODIGO AMERICANO DE COLORES: O2 - VERDE. DOS CIRCUITOS DE PACIENTE REUSABLES LIBRES DE LATEX (INCLUYE ADAPTADORES CONECTORES Y TRAMPAS DE AGUA). O DIEZ CIRCUITOS DESECHABLES LIBRES DE LATEX PARA PACIENTE ADULTO Y/O PEDIATRICO. DOS SENSORES DE FLUJO DE ADULTO Y DOS SENSORES DE FLUJO PEDIATRICO EN CASO DE QUE LA TECNOLOGIA ASI LO REQUIERA. DIEZ NARICES ARTIFICIALES / FILTRO HME (INTERCAMBIADOR DE HUMEDAD Y TEMPERATURA) PARA USO PEDIATRICO / ADULTO DE ACUERDO A LOS REQUERIMIENTOS DE LA UNIDAD. DIEZ MASCARILLAS DESECHABLES LIBRES DE LATEX PARA VENTILACION NO INVASIVA. TAMAÑO DE ACUERDO A LOS REQUERIMIENTOS DE LA UNIDAD."
        },
        "quantity": 1,
        "additionalClassifications": [
          {
            "scheme": "CUCOP-partida",
            "id": "53101",
            "description": "EQUIPO MEDICO Y DE LABORATORIO"
          }
        ],
        "unit": {
          "name": "UNIDAD",
          "value": {
            "amount": 356304.46,
            "currency": "MXN"
          }
        }
      }
    ],
    "documents": [
      {
        "id": "1",
        "title": "2 convocaLA-221.doc",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/b329c5a034904b38b20e07a0aaffa3e1/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2025-12-04T05:00:20.870Z"
      },
      {
        "id": "2",
        "title": "6 difer1oAA221.pdf",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/b329c5a034904b38b20e07a0aaffa3e1/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2025-12-04T05:01:49.363Z"
      },
      {
        "id": "3",
        "title": "Difer1oLA221.pdf",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/b329c5a034904b38b20e07a0aaffa3e1/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2025-12-04T05:01:59.147Z"
      },
      {
        "id": "4",
        "title": "2 convocaLA-221.doc",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/b329c5a034904b38b20e07a0aaffa3e1/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2025-12-04T05:01:35.647Z"
      },
      {
        "id": "5",
        "title": "Mod d contrato.docx",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/b329c5a034904b38b20e07a0aaffa3e1/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2025-12-04T05:01:36.839Z"
      },
      {
        "id": "6",
        "title": "3 juntaLA221ini.pdf",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/b329c5a034904b38b20e07a0aaffa3e1/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2025-12-04T05:01:40.266Z"
      },
      {
        "id": "7",
        "title": "JuntaAclarLA221.doc",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/b329c5a034904b38b20e07a0aaffa3e1/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2025-12-04T05:01:43.706Z"
      },
      {
        "id": "8",
        "title": "4 juntaLA221fin.pdf",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/b329c5a034904b38b20e07a0aaffa3e1/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2025-12-04T05:01:45.990Z"
      },
      {
        "id": "9",
        "title": "5 aperturaLA221.pdf",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/b329c5a034904b38b20e07a0aaffa3e1/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2025-12-04T05:01:47.597Z"
      },
      {
        "id": "10",
        "title": "8 falloAA221.pdf",
        "url": "https://comprasmx.buengobierno.gob.mx/sitiopublico/#/sitiopublico/detalle/b329c5a034904b38b20e07a0aaffa3e1/procedimiento",
        "documentType": "biddingDocuments",
        "datePublished": "2025-12-04T05:02:04.481Z"
      }
    ]
  },
  "awards": [
    {
      "id": "1",
      "status": "active",
      "date": "2025-09-05T17:00:00.000Z",
      "suppliers": [
        {
          "id": "MEDICAL ADVANCED SUPPLIES SA DE CV",
          "name": "MEDICAL ADVANCED SUPPLIES SA DE CV"
        }
      ],
      "value": {
        "amount": 951200,
        "currency": "MXN"
      },
      "contractPeriod": {
        "startDate": "2025-09-06T06:00:00.000Z",
        "endDate": "2025-12-31T06:00:00.000Z"
      }
    },
    {
      "id": "2",
      "status": "active",
      "date": "2025-09-05T17:00:00.000Z",
      "suppliers": [
        {
          "id": "SERVICIOS DE INGENIERIA EN MEDICINA SA DE CV",
          "name": "SERVICIOS DE INGENIERIA EN MEDICINA SA DE CV"
        }
      ],
      "value": {
        "amount": 413313.17,
        "currency": "MXN"
      },
      "contractPeriod": {
        "startDate": "2025-09-06T06:00:00.000Z",
        "endDate": "2025-12-31T06:00:00.000Z"
      }
    }
  ],
  "contracts": [
    {
      "id": "C-2025-00097081",
      "awardID": "1",
      "status": "active",
      "title": "ADQUISICIÓN DE EQUIPOS MÉDICOS SINIESTRADOS",
      "period": {
        "startDate": "2025-09-06T06:00:00.000Z",
        "endDate": "2025-12-31T06:00:00.000Z"
      },
      "value": {
        "amount": 951200,
        "currency": "MXN"
      }
    },
    {
      "id": "C-2025-00097086",
      "awardID": "2",
      "status": "active",
      "title": "ADQUISICIÓN DE EQUIPOS MÉDICOS SINIESTRADOS",
      "period": {
        "startDate": "2025-09-06T06:00:00.000Z",
        "endDate": "2025-12-31T06:00:00.000Z"
      },
      "value": {
        "amount": 413313.17,
        "currency": "MXN"
      }
    }
  ],
  "extensions": {
    "source": "ComprasMX",
    "canonical": "https://postor.com.mx/licitacion/la-50-gyr-050gyr022-t-221-2025",
    "license": "https://creativecommons.org/licenses/by/4.0/",
    "ocidPrefixRegistered": false
  }
}